(289) 809-9071

Home / Services / Well Pumps & Pressure Tanks

Well Pumps & Pressure Tanks

Upfront flat-rate pricing · No hidden fees

A well pressure tank with its pressure switch, shut-off valve and supply line.

A house on a private well relies on two pieces of equipment that city homes never think about: the pump that lifts water out of the well, and the pressure tank that stores it so the pump is not starting every time a tap opens. When either one fails, the house loses water or the pressure swings between strong and weak.

Well Pump Repair and Replacement

Most wells use a submersible pump hung down inside the well casing. Some shallow or older wells use a jet pump mounted in the basement instead. A pump that hums but delivers no water, one that trips its breaker, and one that never shuts off each point to a different fault, so we find which part failed before quoting a new pump.

Pressure Tanks and Pressure Switches

The pressure tank holds a cushion of air, usually behind a rubber bladder. When the bladder tears or the air charge leaks away, the tank fills with water and the pump starts and stops every few seconds. That short cycling burns out pumps early. We check the air charge, replace waterlogged tanks, and repair or replace the pressure switch that tells the pump when to run.

Weak pressure on a well is not always the pump. A plugged sediment filter or a switch set too low gives the same symptom, so we test the equipment beside the tank before anything comes out of the well.

Signs of a Well System Problem

Testing Your Well Water

Public Health Ontario tests private well water for E. coli and total coliforms, the bacteria that indicate contamination. Sample kits are available from local public health units and Public Health Ontario laboratories. The province recommends testing a private well three times a year, and any E. coli in a sample means the water is not safe to drink. These tests do not cover chemicals, so a clean result is about bacteria only.

Wells and Power Outages

A well pump runs on electricity, so a house on a well loses water once the pressure tank empties during an outage. A generator sized for the pump, connected by an electrician through a proper transfer switch, keeps the water running.

Well Pumps & Pressure Tanks Across the GTA

We send plumbers for this work across Toronto, the GTA, and the surrounding regions. It is one of the most needed services in Caledon, Cheltenham, Alton, Halton Hills, Brookville, Kleinburg, King City and Schomberg. See all service areas.

Well Pump and Pressure Tank Questions

What pressure should a well system run at?

A well system runs between two pressures set on the pressure switch, commonly 30 and 50 psi or 40 and 60 psi. The pressure you feel depends on those settings and on how far the tank has drawn down.

What size pressure tank do I need?

The tank is matched to the pump's flow rate so the pump runs long enough each time it starts. A tank that is too small makes the pump start more often, which shortens its life.

Should I test my water after pump work?

It is a good idea to test after any work on the well or after flooding near the wellhead, since either can let bacteria into the system.

Other services

Drain Cleaning & Snaking · Emergency Plumbing & Leak Repair · Toilet & Fixture Repair · Sump Pump Services · Water Heater Services · Sewer & Camera Inspection · Water Line Repair & Replacement · Basement Flooding & Leak Repair

Open 24/7

Need a Plumber Now?